Casella noise dosimeters

Casella Noise Dosimeters
CEL 350 dBadge Micro Noise Dosimeter

CEL 350 dBadge noise dosimeter The CEL-350 is a completely new interpretation of the classic noise dosimeter. It has all the advantages of earlier badge designs such as small size and light weight and yet it still provides all of the benefits that users have come to expect from a traditional noise dosimeter. Fully featured and able to satisfy all current and future noise dosimetry protocols during a single run. The CEL-350 is an ideal instrument for experienced and new users of noise dosimeters. No setup to worry about since the unit stores all data for later investigation and analysis using post-applied analysis and reporting criteria.
Key Benefits
  • L ightweight less than 2.4 oz
  • Small size only 2.8 in long and 1.7 in wide and 2.0 in tall
  • Quick battery recharge in less than 90 mins from completely empty
  • Stores everything for later review
  • Calculates all the popular noise dose parameters
  • Time history profiling of 4 results at fixed 1 m intervals
  • Wide dynamic range from 65 to a full 140 dB
  • Measures simultaneously 3 dB and 5 dB exchange rates
  • Lockable for security
  • Direct automatic calibration with standard acoustic calibrator with ½” cavity

Specifications

Acoustic accuracy ANSI S1.25, IEC61252 2002 Personal sound exposure meters
Dynamic range (dB) 65 to 140
Frequency weightings A for rms values plus Z and C for peak measurements
Time weightings Slow for Q=5 data plus non for Q=3 data as required for standards
Exchange rate (Q dB) 5 and 3 simultaneously
Threshold level (dB) Any levels from 70 to 90 in 1 dB steps
Criterion level (dB) Any level between 70 and 90 in 1 dB steps
Microphone capsule Removable ½” type 2 device can be calibrated with any standard acoustic calibrator using ½” diameter cavity
Calibration method Automatic recognition and calibration to user set dB level
Display screen 96 x 26 pixel graphics LCD with 2 line text messages
Alarm warning indicators Red and blue LED’s showing level noise exceedances during run
Indicators 2 stage hi intensity LED’s for memory, battery or noise warnings
User controls 2 push buttons for On/Off and OK/Accept
Weight (oz, g) < 2.4 oz (68 g)
Size (in, mm) < 2.8 x 1.7 x 2.0 in (72 x 42 x 52 mm)
Case molding Case molding
Battery pack Two half AAA size NiMH rechargeable cells
Battery life (hr) 32 hours continuous, unit gives expected remaining battery life in hours when switched on by “fuel gauge” display icon
Charging unit 3 way dBadge master charger base with drop in charging via connections on back of dBadge casing
Memory storage (results) At least 180 hours at 4 profiles every minute with unit showing remaining memory recording time in hours when switched on
Stored profile values Lavg(Q=5), LZpk, Leq(Q=3), LCpk
Storage interval Fixed 1 minute for all 4 results simultaneously
Real time clock Date and time stamp on all calibration data and profile results
Fixing method to worker Various fixing clips provided for clothing and hard hat mounting
Security features dBadge can be locked prior to being left on worker to prevent tampering - showing only duration and run in progress on display
Languages Up to 5 standard languages can be selected for screen prompts, English, Spanish, French, German, Italian
Identification of multiple units 2 line text string can be uploaded from dB35 pc program
 

Ordering information

CEL-350/K1 Single pack dBadge noise dosimeter kit with standard accessories
CEL-350/K2 Twin pack dBadge noise dosimeter kit with standard accessories
CEL-350/K5 Five pack dBadge noise dosimeter kit with standard accessories
CEL-350/K10 Ten pack dBadge noise dosimeter kit with standard accessories
CEL-350 Single dBadge micro noise badge unit with mounting clips and windscreen
CEL-110/2 Class 2 acoustic calibrator 114 dB at 1 kHz
CEL-6350 3 way drop in rapid master charger including PC18 universal power supply (can be “daisy chained” together for multiple kits with CEL-6358 slave charger unit)
CEL-6358 Slave charger unit and link cable to master charger for up to 3 additional dosimeters
CEL-6357 dB35 Windows based download and database software package supplied on CD
CMC39 Infrared adapter for PC download and programming
CEL-6355 Multi pack kit case with space for up to 12 dBadge dosimeters and accessories
All kits include CEL-350 dBadge dosimeter(s) with various fixing clips and foam windscreen, CEL-110/2 acoustic calibrator, 3 way charger base unit and power supply, slave charger unit(s), infrared download adapter, RS232 to USB adapter, pc software, kit case
Return to top

Return to SMG/interlink®
For more information  Email Mail  SMG/Interlink®
Interlink Marketing Corporation
dba SMG/interlink®
PO Box 260795
Plano, Texas 75026
Toll free 1-800-804-6196
Ph: 972-985-0883
Fx: 972-985-3252
2203 Glen Forest Ln
Plano, Texas 75023

credit card logos

Copyright © 1997-2012 Interlink Marketing Corporation

SiteLock