Home button About button
Blog button
       

SMG/interlink®
Serving our customers since 1994

Instruments for Environmental, Health and Safety Professionals,
HVAC Engineers and Technicians, Manufacturing Engineers,
Quality Control and Laboratory Professionals
 
Zephyr ll and Zephyr II+ Micromanometers

GrayWolf Solomat Zephyr ll and Zephyr II+ Micromanometers
with auto zeroing

Zephyr II+ micro-manometer with three function probe
Zephyr II+ with three function probe
Differential pressure is a crucial parameter for monitoring Indoor Air Quality (IAQ) and is a key measurement for HVAC servicing and setup. 

The Zephyr II micromanometers are designed to measure differential pressure, static pressure and temperature. The Zephyr II instruments have a built-in auto-zeroing micro-manometer, a 'K'-type thermocouple input and 2 BIN type connectors. Used with a pitot tube, the Zephyr II provides direct air velocity readings. Optional probes such as the telescoping 3-function “smart” probe for temperature, humidity and air flow (hot wire) can be quickly connected. The auto-zeroing feature allows for highly accurate differential pressure logging over time.

Zephyr II instruments are designed with the user in mind. The large rubber grip and membrane switch pad ensure comfortable use and one-hand operation, even with gloves on. The optional 3-function probe attaches to the side of the instrument for one-handed operation.

The display and menu system provide step-by-step guides for each operation ensuring minimal need for user training. Data capture is standard and facilitates duct traversing and direct volumetric flow calculations when the size of the duct is entered. 

Zephyr II instruments are stand-alone. The Zephyr II+ with on-board memory can be interfaced to any GrayWolf,  WolfSense, PPC or LAP mobile PC based system via a CF serial card (model ACC-SCDPC) providing the full capabilities of GrayWolf's WolfSense software. 

Specifications for Zephyr II Micromanometer

Inputs availableAuto-zeroing micro-manometer (built-in)
`K' type thermocouple
3-Function %RH, Temperature, (hotwire) Air Velocity Probe
Power requirements3 x C size disposable alkaline batteries
Optional AC adapter 100 to 240V AC 50/60Hz
Rechargeable batteries and separate charger may be used
Typical battery life130 Hours – subject to type of probes fitted.
Pressure Range± 7,000 Pa, ± 30 in H2O, ± 700 mm H2O, ± 70 mbar, ± 50 mmHg
Pressure Resolution0.1 PA, 0.001 in H2O, 0.01 mmH2O, 0.001 mbar, 0.001 mmHg
Pressure Accuracy± 1% of reading, ± 2 counts
Operating temperature0°C to 50°C (32F to 122°F)
Operating humidity0 to 90% RH
MaterialImpact resistant ABS, water resistant to IP54
Ingress protectionIP54
Dimensions265mm x 135mm x 42mm
(10-1/2" x 5-1/4" x 1-1/2")
Weight0.9Kg (2 lbs) 
Manual data capture and review

Zephyr II

Zephyr II+

No
Yes
Averaging facility for duct traversing
Yes
Yes
Trend (timed) datalogging
No
Yes
Data download to PC
No
Yes
Optional interface to mobile PCs via GrayWolf WolfSense software
Yes
Yes

Standard Zephyr II Micromanometer Kits

 

CLK-Zephyr II

CLK-Zephyr II+

Kit Contents
  • Zephyr II instrument
  • 6’ Dual Tubing
  • Hard Shell Carrying Case
  • Zephyr II+ instrument with case
  • 6’ Dual Tubing
  • PC Serial Computer Cable
  • WolfSense Data Analysis Software
Possible measurements include:
Differential pressureYesYes
TemperatureYes ('K' type thermocoupl or RTD)Yes (`K' type thermocouple or RTD)
Air velocityYes (pitot static tube or hot wire required)Yes (pitot static tube or hot wire required)
Volumetric flow rateYes (pitot tube or hot wire required) Yes (pitot tube or hot wire required) 
Static pressureYesYes
HumidityNoYes
Dew pointYes Yes

Zephyr Micromanometer Probe Compatibility Matrix

Probe Availability
Zephyr II
Zephyr II+
1260GSSIAQ Four Function NDIR Smart Probe
No
No
2300AHTS3 Function AHT Telescoping Smart Probe
(Temperature, Humidity, Air Flow with Hot Wire Thermoanemometer)
Yes
Yes
Pitot Static ProbesPIT-229MS 200mm x 4mm (8" x 0.16")
Yes
Yes
PIT-229MM 500mm x 8mm (19.5" x 0.32")
Yes
Yes
PIT-229ML 1000mm x 8mm (39.5" x 0.32")
Yes
Yes
PIT-229EXT 200mm (MAX) x 4mm (38" x 1/8")
Yes
Yes
PIT-229MS 1300mm (MAX) x 8mm (51.25" x 0.32")
Yes
Yes
TemperatureNumerous Thermocouple Temperature Probes
Yes
Yes
  • Will not do CO or CO2 gas measurements
  • For technical data or alternative measurements refer to individual probe datasheets 
Zephyr ll and Zephyr II+ Micromanometers
 
Back

Return to SMG/interlink®
For more information  Email Mail  SMG/Interlink®
Interlink Marketing Corporation
dba SMG/interlink®
PO Box 260795
Plano, Texas 75026
Toll free 1-800-804-6196
Ph: 972-985-0883
Fx: 972-985-3252
2203 Glen Forest Ln
Plano, Texas 75023

credit card logos

Copyright © 1997-2012 Interlink Marketing Corporation