Data Collection Form

Optimizer Collect
Graphical Output
|
With Bios
Optimizer™ software, you will do more
with your critical calibration data. Optimizer Collect Light provides
a RS-232 to Microsoft Excel® interface for the Defender 500 series,
the Definer 220 and 1020 and the Met Lab Series. Optimizer Collect
light is provided with the purchase of a DryCal® or can be purchased
separately from Bios for a nominal fee.
Optimizer Collect
light includes templates to:
- Capture flow data from your Bios DryCal® directly to a Microsoft
Excel® preconfigured Spreadsheet.
- Enter flow
rates from pumps or other flow source and calibrate the flow
source. Data is recorded directly to a preconfigured
Microsoft
Excel® Spreadsheet.
- Enter flow
data from a flow meter and capture and compare the flow measurements
from your Bios DryCal® precision calibrator into
a preconfigured Microsoft Excel® Spreadsheet.
Optimizer
Collect Light is upgradeable to a full version of Collect by
purchasing an Activation code from Bios for
automatic multi-point
calibration of MFC/MFM using DryCal® and Integrator 110.
Optimizer
Collect gives you the added ability to:
- Connect
to any RS232 instrument to any program: Directly to Microsoft
Excel® using DIRECT-XL™ technology, write directly
to files, databases, or 'wedge' into any Windows® program.
- Instrument
Library: Pre-configured
interfaces for over 500 different instrument models. BIOS
methods to calibrate
analogue MFCs and MFMs
in conjunction with the Bios Integrator are provided.
- Hotkey
Commands: Start
and stop instrument commands using any keyboard key.
- Method
Library: Pre-configured Methods including Excel® templates
for many common applications. Additional Bios templates
for analogue MFC calibrations with the use of the Bios
Integrator.
- Speedy
processing: Send
commands at a rate of 10 per second, receive and process incoming
data at rate of over
20 per second.
- Extra
information for readings: Add
Date, Time, Milliseconds and User ID meta-data to instrument
readings.
- Timed
interval data collection setting: Collect data at
a defined frequency with option to stop
after
a number
of readings.
- Multiple
instrument support: Connect
and run multiple instruments interfaces simultaneously.
- Filter
and Discard data options: Filter
incoming data to convert characters to strings or strings
to characters
or discard unwanted
or erroneous outputs.
- Powerful
Parser: Easy
to setup parser, handles simple to complex raw data outputs
to extract
only required
readings.
- Communication
protocols: Support
connecting slave devices using Modbus or clinical
analyzers with
ASTM 1381.
- Free
RS232-to-TCP/IP software utility: Connect
remote instruments directly to
any computer
with Collect
installed, over your
network.
- TCP/IP
Ethernet data collector: Connect instruments or converters
TCP/IP
Ethernet port directly
to any computer
with Collect
installed.
PC Requirements to run Optimizer Collect light and Optimizer Collect
Windows® XP, Windows® Vista (32 bit version), Windows® 7
Microsoft Excel® 2000, 2003, 2007
RS232 port, or USB to RS-232 adapter.
|