Biosystems Product Information
| Biosystems
Cannonball3 Portable
Multi Gas Detector LEL (flammable), Ammonia, NH3, H2S, NO2, SO2, Cl2, CO,
O2 from Biosystems div
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
DESIGN
PUMPS
RECORDING
SMART SENSORS AND CALIBRATION
| Size: | 12" x 6" x 6". |
| Weight: | Alkaline battery
version 6.7 lb. NiMH battery version 6.5 lb. |
| Intrinsic Safety |
UL Class I Division 1 Groups A,B,C,D Temp T3C. CSA Class I Division 1 Groups A,B,C,D Exia Temp T3C. |
| Durability | Meets IPX5 water standard. |
| Display | Oversized LCD display. |
| Audible Alarm | Two-toned alarm rated at 105 dB @ 30 cm |
| Visual Alarm | Three bright red multi directional LED alarms. |
| Display Backlight | Automatically-activated. |
| Controls | One-button automatic calibration. |
| Housing | Chrome metal-plated ABS. Internal RFI shielding provides RFI immunity to 40 V/m. |
| Battery Options | Alkaline or rechargeable NiMH (Nickel Metal Hydride) battery packs. |
| Run Time | 16 hrs NiMH, 24 hrs Alkaline. |
|
Cannonball3 Sensors Installed |
Standard Version (1 pump) |
Dilution Version (2 Pumps) |
||
|
Alkaline (A) |
NiMH (N) |
Alkaline (A) |
>NiMH (N) |
|
|
No Sensors Installed |
54-34-00000-A |
54-34-00000-N |
54-35-00000-A |
54-35-00000-N |
|
LEL / O |
54-34-30000-A |
54-34-30000-N |
54-35-30000-A |
54-35-30000-N |
|
LEL / O / CO |
54-34-30100-A |
54-34-30100-N |
54-35-30100-A |
54-35-30100-N |
|
LEL / O / CO-H |
54-34-31900-A |
54-34-31900-N |
54-35-31900-A |
54-35-31900-N |
|
LEL / O / H2S |
54-34-30200-A |
54-34-30200-N |
54-35-30200-A |
54-35-30200-N |
|
LEL / O / Duo-Tox (CO/H2S) |
54-34-31400-A |
54-34-31400-N |
54-35-31400-A |
54-35-31400-N |
|
LEL / O / CO / H2S |
54-34-30102-A |
54-34-30102-N |
54-35-30102-A |
54-35-30102-N |
|
LEL / O / SO2 |
54-34-30300-A |
54-34-30300-N |
54-35-30300-A |
54-35-30300-N |
|
LEL / O / CO / SO2 |
54-34-30103-A |
54-34-30103-N |
54-35-30103-A |
54-35-30103-N |
|
LEL / O / H2S / SO2 |
54-34-30203-A |
54-34-30203-N |
54-35-30203-A |
54-35-30203-N |
|
LEL / O / Duo-Tox (CO/H2S)/SO2 |
54-34-31403-A |
54-34-31403-N |
54-35-31403-A |
54-35-31403-N |
|
LEL / O / SO2 Ext. |
54-34-31500-A |
54-34-31500-N |
54-35-31500-A |
54-35-31500-N |
|
LEL / O / NH3 |
54-34-32100-A |
54-34-32100-N |
54-35-32100-A |
54-35-32100-N |
|
LEL / O / CI2 (non-specific) |
54-34-30800-A |
54-34-30800-N |
54-35-30800-A |
54-35-30800-N |
|
LEL
/ O / CI2 (specific) |
54-34-31800-A |
54-34-31800-N |
54-35-31800-A |
54-35-31800-N |
|
LEL
/ O, / NO2 |
54-34-30900-A |
54-34-30900-N |
54-35-30900-A |
54-35-30900-N |
|
The dilution version of the Cannonball3 allows for accurate gas detection in inert environments without the use of a dilution orifice. |
||||
| The
detection range of the standard SO2 sensor is
0.0 - 25 in 0.1 PPM increments. The detection range of the extended range SO2 sensor is 0 - 100 in 1 PPM increments |
||||
|
Option |
Code |
Comments |
|
Alkaline
|
A |
NiMH
battery pack and charger may be purchased separately. |
|
Rechargeable |
N |
NiMH
configuration includes charger. Alkaline battery packs may be purchased |
|
Datalogging |
D |
Enables
the Cannonball3 to record and download measurements. This option is available
as an upgrade after purchase. Download software must be purchased separately.
Computer must support IrDA to download. |
|
Remote
Alarm |
R |
Remote
alarm connector is required to connect an optional remote alarm device. Remote
alarm device must be purchased separately. |
|
Part
No. |
Description |
|
Range |
Resolution | |
|
54-25-80 |
LEL |
Combustible
Gas |
|
0
-100% LEL |
1
% LEL |
|
54-25-90 |
O2 |
Oxygen |
|
0
-30%/Vol |
0.1% |
|
54-25-01 |
CO |
Carbon
monoxide |
|
0
-1000 PPM |
1
PPM |
|
54-25-05 |
|
CO
Plus dual purpose CO / H2S |
CO: |
0
-1000 PPM |
1
PPM |
|
54-25-19 |
CO-H |
CO
Minus, reduced sensitivity to H2 |
|
0
-800 PPM |
1
PPM |
|
54-25-02 |
H2S |
Hydrogen
sulfide |
|
0
-200 PPM |
1
PPM |
|
54-25-14 |
Duo-Tox |
Dual
channel CO/ H2S Provides substance specific readouts |
CO: H2S: |
0-1000
PPM 0-200 PPM |
1
PPM 1 PPM |
|
54-25-03 |
SO2 |
Sulfur
dioxide |
|
0-25
PPM |
0.1
PPM |
|
54-25-15 |
SO2-Ext |
Sulfur
dioxide extended range |
|
0-100
PPM |
1
PPM |
|
54-25-211 |
NH3 |
Ammonia |
|
0-300
PPM |
1
PPM |
|
54-25-081 |
CI2 |
Chlorine
(non-specific) |
|
0-50
PPM |
0.1
PPM |
|
54-25-181 |
CI2 |
Chlorine
(specific) |
|
0-50
PPM |
0.1
PPM |
|
54-25-091 |
NO2 |
Nitrogen
dioxide |
|
0-50
PPM |
0.1
PPM |
|
1. Special reactive gas calibration adapter (54-36-16) required for proper calibration. Inert tubing is required for proper calibration and remote sampling | |||||
|
The
non-specific Cl2 sensor detects both Cl2 and ClO2
gases.
The
specific Cl2 sensor is designed for the target gas only.
| |||||
|
Part
No. |
Description |
|
35-0379 |
Cannonball3
motorized sample draw pump module |
|
35-0378 | Cannonball3
motorized sample draw pump module for dual pump version (2 pumps). The Cannonball3 must be configured for dual pump. |
|
54-36-01 |
Cannonball3
Remote audible and visible alarm. |
|
35-0376 |
Cannonball3 Alkaline
batter pack ("D"-Cell batteries not included) |
|
35-0377 |
Cannonball3
NiMH battery pack |
|
54-26-0603 |
Cannonball3
BioTrak Software Kit. Includes BioTrak software and manual' |
|
54-26-0605 |
Infrared
communication device Serial - IrDA - Requires
one available PC serial port. |
|
Part
No. |
Description |
|
13-174 |
Cannonball3
Reference Manual |
|
13-175 |
Cannonball3
Quick Reference Guide |
|
22-143 |
Cannonball3
Training Video |
|
42-002 |
Cannonball3
Shoulder strap |
|
54-36-20 |
Cannonball3
Gasket service kit. Includes 6 filter gaskets,
2 pump gasket, 2 battery gasket and lubricant for gaskets |
|
54-36-17 |
Internal
filter kit for Cannonball3. (10 ea. particulate and 5 ea. hydrophobic). |
|
Part
No. |
Description |
|
35-0379 |
Cannonball3
motorized sample draw pump |
|
35-0378 |
Cannonball3
motorized
sample draw pumps for dual pump version. The
Cannonball3 must be configured for dual pump. |
|
54-36-03 |
Cannonball3
Sample
probe with plastic extension and male quick disconnect |
|
54-36-04 |
Cannonball3
Sample
probe with stainless steel extension and male quick disconnect |
|
54-36-05 |
Cannonball3
Sample
probe with plastic extension and threaded for quick disconnect fitting. |
|
54-36-06 |
Cannonball3
Sample
probe with stainless steel extension and threaded for quick disconnect fitting |
|
54-36-07 |
Cannonball3
Sample
probe male quick disconnect |
|
54-36-08-010 |
Cannonball3
Extension
hose, 10 feet with male and female quick disconnect |
|
54-36-08-025 |
Cannonball3
Extension hose, 25 feet with male and female quick disconnect |
|
54-36-08-050 |
Cannonball3
Extension
hose. 50 feet with male and female quick disconnect |
|
54-36-08-100 |
Cannonball3
Extension hose, 100 feet with male and female quick disconnect |
|
54-36-09 |
Cannonball3
set of male and female quick disconnects |
|
54-36-01 |
Cannonball3
Remote audible and visible alarm |
|
Part
No. |
Description |
|
54-36-10 |
Cannonball3
Snap-On fast charger 110VAC |
|
54-36-11 |
Cannonball3
Snap-On fast charger 12VDC (Available 3' Qtr 2001 |
|
35-0376 |
Cannonball3
Alkaline batter pack batteries not included |
|
35-0377 |
Cannonball3
NiMH battery pack |
|
54-36-13 |
Cannonball3
Data logger upgrade. Download software not included. |
|
54-26-0603 |
Cannonball3
BioTrak Software Kit. Includes BioTrak software and manual |
|
54-26-0605 |
Infrared
communication device Serial - IrDA - Requires
one available PC serial port. |
|
Computer
must be equipped with infrared adapter (IrDA) to download | |
|
Part
No. |
Description |
|
54-36-14 |
Cannonball3
Calibration kit. Includes foam-lined carrying case with room for up to three cylinders
of calibration gas. Kit contains 12-023 regulator and other fittings. Kit does
not include gas. |
|
35-0453 |
Cannonball3 Waterproof "Pelican" style
carrying case with room for one Cannonball3 and one
cylinder of calibration gas |
|
54-36-15 |
Cannonball3
Calibration tube with male quick disconnect |
|
54-36-18 |
Cannonball3
Calibration balloon ( not for use with CL2 and CIO2). |
|
54-36-16 |
Cannonball3
Inert calibration tube (for reactive gases) with male quick disconnect |
| Return
to SMG/interlink® Copyright © 1997-2012 Interlink Marketing Corporation Home | Anemometers | Borescopes | Calibration gases | Gas detectors | Heat stress monitors | IAQ monitors | IR cameras | Light/UV meters | Manometers | Moisture meters | Noise dosimeters | pH meters | Pitot tubes| Radiation meters | Sampling pumps | Sound meters | Thermometers | Other resources
|