Home button About button
Blog button
       

SMG/interlink®
Serving our customers since 1994

Instruments for Environmental, Health and Safety Professionals,
HVAC Engineers and Technicians, Manufacturing Engineers,
Quality Control and Laboratory Professionals

 

Biosystems Product Information

Multi-Gas Portables
Single Gas Portables
Accessories

PosiChek3 SCBA Test Bench

Posi USB SCBA Test Bench
Calibration Gases

Biosystems Cannonball3 Portable Multi Gas Detector LEL (flammable), Ammonia, NH3, H2S, NO2, SO2, Cl2, CO, O2 from Biosystems div
Honeywell Analytics

Biosystems Honeywell logo


Biosystems Cannonball3 portable multi gas meter for hazardous locations can simultaneously detect up to 5 different gases including LEL, ammonia, H2S, NO2, SO2, Cl2, CO, O2, or methane. Available in a high sensitivity ppm hydrocarbon configuration or dual pumps for accurate dilution monitoring in inert (oxygen-free) environments

Cannonball 3 multi gas hazardous gasmonitorBiosystems Cannonball3

The Cannonball3 stands up to the harshest environmental conditions while delivering the quality and performance that you've come to expect from Biosystems. 

The Cannonball3 can be configured to monitor oxygen, combustible gases and vapors and many toxic gases. With Biosystems' "Duo-Tox" sensor installed, the Cannonball3 can simultaneously detect up to 5 different gases. It is also available in the PPM hydrocarbon configuration.

The Cannonball3 is housed in a durable impact-resistant case that is completely sealed from the outside elements, ensuring that it will operate reliably in even the most demanding environments. Three different LED alarm lights guarantee that visible alarms can be seen from any angle. The graphics display is the largest in its class, making it easy to read even from a distance. 

All procedures necessary for day-to-day operation, including fully automatic calibration adjustment, are controlled through a single button. Instrument configuration options and other higher functions are accessed with the four navigation arrows on the top of the instrument. 

The Cannonball3 is available in either rechargeable (NiMH) or disposable alkaline battery versions. The NiMH version will provide at least 16 continuous hours of operation even with the display back light continuously on. The Alkaline version will provide at least 24 hours of continuous operation in similar conditions.

Standard Accessories: Each Cannonball3 detector is shipped complete with probe assembly including 10 feet of tubing, reference manual, shoulder strap and probe and instrument filter replacement kits. Rechargeable detectors include battery charger and internally-housed nickel metal hydride (NiMH) battery pack. Alkaline PhD Lite Detectors include the internally-housed alkaline battery pack and 5 disposable D-cell batteries.

Biosystems Cannonball3 Features

DESIGN

  • Rugged RFI-protected case designed for the most demanding environments
  • IP65 rated protection against dust and water 
  • One button operation
  • Oversized  (5" diagonal) backlit graphic display with automatic backlight
  • Super bright alarm lights visible in any direction
  • Multiple languages
  • PUMPS

  • Field replaceable pump module
  • Available with dual pumps for accurate dilution monitoring in inert environments without the use a dilution orifice
  • Dilution calibration regardless of tube length 
  • Automatic low flow alarm
  • Automatic leak test before every use
  • RECORDING

  • Black Box recorder with over 100 hours of storage 
  • Available with optional datalogging for convenient and easy downloading to a computer
  • SMART SENSORS AND CALIBRATION

  • Four sensors. O2, LEL and up to three toxic channels using Biosystems' Duo-Tox two channel CO/H2S sensor (see matrix for available sensors) 
  • User replaceable sensors
  • One button auto calibration 
  • Calibration due reminder
  • Sensor span reserve indicators during calibration for predictive maintenance
  • PPM hydrocarbon configuration
  • Interchangeable Alkaline (5 "D"-cell) and rechargeable (NiMH) batteries 
  • Operating life up to 24 hours - alkaline; 16 hours NiMH
  • Snap-On fast charger included with rechargeable (NiMH) configuration
  • Recharges in 4 hours
  •  Specifications  Common Configurations  Options 
    Sensors  Calibration Kits   Accessories 

    Biosystems Cannonball3 Specifications

    Size: 12" x 6" x 6".
    Weight: Alkaline battery version 6.7 lb.
    NiMH battery version 6.5 lb.
    Intrinsic Safety UL Class I Division 1 Groups A,B,C,D Temp T3C.
    CSA Class I Division 1 Groups A,B,C,D Exia Temp T3C.
    Durability Meets IPX5 water standard.
    Display Oversized LCD display.
    Audible Alarm Two-toned alarm rated at 105 dB @ 30 cm
    Visual Alarm Three bright red multi directional LED alarms.
    Display Backlight Automatically-activated.
    Controls One-button automatic calibration.
    Housing Chrome metal-plated ABS. Internal RFI shielding provides RFI immunity to 40 V/m.
    Battery Options Alkaline or rechargeable NiMH (Nickel Metal Hydride) battery packs.
    Run Time 16 hrs NiMH, 24 hrs Alkaline.


    Biosystems Cannonball3 Gas Detector Most Common Configurations

    Cannonball3

    Sensors Installed

    Standard Version (1 pump)

    Dilution Version (2 Pumps)

    Alkaline

    (A)

    NiMH

    (N)

    Alkaline  

    (A)

    >NiMH

     (N)

    No Sensors Installed

    54-34-00000-A

    54-34-00000-N

     54-35-00000-A   

    54-35-00000-N

    LEL / O

    54-34-30000-A

    54-34-30000-N

    54-35-30000-A

    54-35-30000-N

    LEL / O / CO

    54-34-30100-A

    54-34-30100-N

    54-35-30100-A

    54-35-30100-N

    LEL / O / CO-H

    54-34-31900-A

    54-34-31900-N

    54-35-31900-A

    54-35-31900-N

    LEL / O / H2S

    54-34-30200-A

    54-34-30200-N

    54-35-30200-A

    54-35-30200-N

    LEL / O / Duo-Tox (CO/H2S)

    54-34-31400-A

    54-34-31400-N

    54-35-31400-A

    54-35-31400-N

    LEL / O / CO / H2S

    54-34-30102-A

    54-34-30102-N

    54-35-30102-A

    54-35-30102-N

    LEL / O / SO2

    54-34-30300-A

    54-34-30300-N

    54-35-30300-A

    54-35-30300-N

    LEL / O / CO / SO2

    54-34-30103-A

    54-34-30103-N

    54-35-30103-A

    54-35-30103-N

    LEL / O / H2S / SO2

    54-34-30203-A

    54-34-30203-N

    54-35-30203-A

    54-35-30203-N

    LEL / O / Duo-Tox (CO/H2S)/SO2

    54-34-31403-A

    54-34-31403-N

    54-35-31403-A

    54-35-31403-N

     LEL / O / SO2 Ext.

    54-34-31500-A

    54-34-31500-N

    54-35-31500-A

    54-35-31500-N

     LEL / O / NH3

    54-34-32100-A

    54-34-32100-N

    54-35-32100-A

    54-35-32100-N

     LEL / O / CI2 (non-specific)

    54-34-30800-A

    54-34-30800-N

    54-35-30800-A

    54-35-30800-N

     LEL / O / CI2 (specific)

    54-34-31800-A

    54-34-31800-N

    54-35-31800-A

    54-35-31800-N

     LEL / O, / NO2

    54-34-30900-A

    54-34-30900-N

    54-35-30900-A

    54-35-30900-N

    The dilution version of the Cannonball3 allows for accurate gas detection in inert environments without the use of a dilution orifice.

    The detection range of the standard SO2 sensor is 0.0 - 25 in 0.1 PPM increments.
    The detection range of the extended range SO2  sensor is 0 - 100 in 1 PPM increments
     


    Biosystems Cannonball3 Options

    Option

     Code

    Comments

    Alkaline

    A

    NiMH battery pack and charger may be purchased separately.

    Rechargeable

    N

    NiMH configuration includes charger. Alkaline battery packs may be purchased
    separately

    Datalogging

    D

    Enables the Cannonball3 to record and download measurements. This option is available as an upgrade after purchase. Download software must be purchased separately. Computer must support IrDA to download.

    Remote Alarm Connector

    R

    Remote alarm connector is required to connect an optional remote alarm device. Remote alarm device must be purchased separately.


    Biosystems Cannonball3 Smart Sensors  

    Part No.

    Description

     

    Range

    Resolution

    54-25-80

    LEL

    Combustible Gas

     

    0 -100% LEL

    1 % LEL

    54-25-90

    O2

    Oxygen

     

    0 -30%/Vol

    0.1%

    54-25-01

    CO

    Carbon monoxide

     

    0 -1000 PPM

    1 PPM

    54-25-05

    CO+

    CO Plus dual purpose CO / H2S
    Provides a non-specific readout for CO & H2S

    CO:
    H2S:

    0 -1000 PPM
    0 - 200 PPM

    1 PPM

    54-25-19

    CO-H

    CO Minus, reduced sensitivity to H2

     

    0 -800 PPM

    1 PPM

    54-25-02

    H2S

    Hydrogen sulfide

     

    0 -200 PPM

    1 PPM

    54-25-14

    Duo-Tox

    Dual channel CO/ H2S
    Provides substance specific readouts for CO & H 2S
    CO:
    H2S:
    0-1000 PPM
    0-200 PPM
    1 PPM
    1 PPM

    54-25-03

    SO2

    Sulfur dioxide

     

    0-25 PPM

    0.1 PPM

    54-25-15

    SO2-Ext

    Sulfur dioxide extended range

     

    0-100 PPM

    1 PPM

    54-25-211

    NH3

    Ammonia

     

    0-300 PPM

    1 PPM

    54-25-081

    CI2

    Chlorine (non-specific)

     

    0-50 PPM

    0.1 PPM

    54-25-181

    CI2

    Chlorine (specific)

     

    0-50 PPM

    0.1 PPM

    54-25-091

    NO2

    Nitrogen dioxide

     

    0-50 PPM

    0.1 PPM

    1.       Special reactive gas calibration adapter (54-36-16) required for proper calibration. Inert tubing is required for proper calibration and remote sampling

    The non-specific Cl2 sensor detects both Cl2 and ClO2 gases.
    The specific Cl2 sensor is designed for the target gas only.


    Most Common Biosystems Cannonball3 Accessories

    Part No.

    Description

    35-0379

    Cannonball3 motorized sample draw pump module

    35-0378

     Cannonball3 motorized sample draw pump module for dual pump version (2 pumps).
     The Cannonball3 must be configured for dual pump.

    54-36-01

    Cannonball3 Remote audible and visible alarm.

    35-0376

    Cannonball3 Alkaline batter pack ("D"-Cell batteries not included)

    35-0377

    Cannonball3 NiMH battery pack

    54-26-0603

    Cannonball3 BioTrak Software Kit. Includes BioTrak software and manual'

    54-26-0605

    Infrared communication device Serial - IrDA - Requires one available PC serial port.


    Biosystems Cannonball3 Miscellaneous Accessories

    Part No.
    Description

    13-174

    Cannonball3  Reference Manual

    13-175

    Cannonball3  Quick Reference Guide

    22-143

    Cannonball3 Training Video

    42-002

    Cannonball3 Shoulder strap

    54-36-20

    Cannonball3  Gasket service kit. Includes 6 filter gaskets, 2 pump gasket, 2 battery gasket and lubricant for gaskets

    54-36-17

    Internal filter kit for Cannonball3. (10 ea. particulate and 5 ea. hydrophobic).


    Biosystems Cannonball3 Remote Sampling Accessories

    Part No.

                                        Description

    35-0379

     Cannonball3 motorized sample draw pump

    35-0378

    Cannonball3 motorized sample draw pumps for dual pump version.

    The Cannonball3 must be configured for dual pump.

    54-36-03

     Cannonball3 Sample probe with plastic extension and male quick disconnect

    54-36-04

     Cannonball3 Sample probe with stainless steel extension and male quick disconnect

    54-36-05

     Cannonball3 Sample probe with plastic extension and threaded for quick disconnect fitting.

    54-36-06

    Cannonball3 Sample probe with stainless steel extension and threaded for quick disconnect fitting

    54-36-07

     Cannonball3 Sample probe male quick disconnect

    54-36-08-010

     Cannonball3 Extension hose, 10 feet with male and female quick disconnect

    54-36-08-025

     Cannonball3 Extension hose, 25 feet with male and female quick disconnect

    54-36-08-050

     Cannonball3 Extension hose. 50 feet with male and female quick disconnect

    54-36-08-100

     Cannonball3 Extension hose, 100 feet with male and female quick disconnect

    54-36-09

     Cannonball3 set of male and female quick disconnects

    54-36-01

     Cannonball3 Remote audible and visible alarm


    Biosystems Cannonball3 Charging and Datalogging Accessories

    Part No.

    Description

    54-36-10

    Cannonball3 Snap-On fast charger 110VAC

    54-36-11

    Cannonball3 Snap-On fast charger 12VDC (Available 3' Qtr 2001

    35-0376

    Cannonball3 Alkaline batter pack batteries not included

    35-0377

    Cannonball3 NiMH battery pack

    54-36-13

    Cannonball3 Data logger upgrade. Download software not included.

    54-26-0603

    Cannonball3 BioTrak Software Kit. Includes BioTrak software and manual

    54-26-0605

    Infrared communication device Serial - IrDA - Requires one available PC serial port.

    Computer must be equipped with infrared adapter (IrDA) to download

    Biosystems Cannonball3 Calibration Materials & Carrying Cases

    Part No.

    Description

     

    54-36-14

    Cannonball3 Calibration kit. Includes foam-lined carrying case with room for up to three cylinders of calibration gas. Kit contains 12-023 regulator and other fittings. Kit does not include gas.

    35-0453

    Cannonball3 Waterproof "Pelican" style carrying case with room for one Cannonball3 and one cylinder of calibration gas

    54-36-15

    Cannonball3 Calibration tube with male quick disconnect

    54-36-18

    Cannonball3 Calibration balloon ( not for use with CL2 and CIO2).

    54-36-16

    Cannonball3 Inert calibration tube (for reactive gases) with male quick disconnect

    Return to top of page


    Return to SMG/interlink®
    For more information  Email Mail  SMG/Interlink®
    Interlink Marketing Corporation
    dba SMG/interlink®
    PO Box 260795
    Plano, Texas 75026
    Toll free 1-800-804-6196
    Ph: 972-985-0883
    Fx: 972-985-3252
    2203 Glen Forest Ln
    Plano, Texas 75023

    credit card logos

    Copyright © 1997-2012 Interlink Marketing Corporation