Biosystems IQ6 Dock™ Automated Docking Station for PhD6
Bump Testing, Calibration, Datalogging, Monitor Diagnostics
Biosystems Honeywell logo

IQ6 Docking Station for PhD6 Detector

The Biosystems IQ6 Dock™ is a fully automated bump test, calibration, meter diagnostics and data download center for the PhD6 gas monitor from Biosystems div Honeywell Safety Products. Placing the meter in the dock initiates the test / calibration data logging sequence.

The IQ6 Dock identifies the instrument, performs a quick battery test which is followed by a bump test. If the detector fails the bump test, the IQ6 automatically performs a full span calibration of the detector, without intervention from the user.

Once the instrument passes the bump test or span calibration, the IQ6 automatically tests the audible, visible and vibrating (if available) alarms before downloading instrument data. Once all the tests are passed, the IQ6 Dock will show "Ready" on the display, letting you know that the meter is ready to go.

The IQ6 Dock comes standard with two configurable gas ports, which is sufficient for most users. A 4-port model is available for users using instruments with a wider variety of sensor options.

Biosystems IQ6 Dock™ Features

Automated Tests

  • Automatic Instrument Identification
  • Automatic Battery Test
  • Automatic Alarm Tests (audible, visible, vibrating)
  • Automatic Bump Test
  • Automatic Calibration (if necessary)
  • Automatic Record Keeping
  • Automatic Ready / Fault indication
  • Bump test in under 45 seconds (O2, LEL, CO, H2S)
  • Calibration in under 2 minutes (O2, LEL, CO, H2S)

Configuration Options

  • Standalone calibration station
  • 2-port docks can process a PhD6 using one multi-gas and one single component cylinders or two single component cylinders
  • 4-port docks can process a PhD6 using one multi-gas cylinder and three single component cylinders or four single component cylinders
  • Connected to PC via USB or Ethernet for enhanced control over calibration and data acquisition during testing.
  • Ethernet capable docks can send e-mail to a specified address when a fault is detected.
  • Single or Multiple Docks
  • Cascade between 1 and 4 docks

Biosystems IQ6 Docking Station Ordering Information

Part number
Description

54-54-9200

IQ6 Dock with fresh air port plus 2 calibration gas inlet ports, software, installation disks and manuals.

54-54-9200N

Ethernet ready IQ6 Dock with fresh air port plus 2 calibration gas inlet ports, software, installation disks and manuals.

54-54-9400

IQ6 Dock with fresh air port plus 4 calibration gas inlet ports, software, installation disks and manuals.

54-54-9400N

Ethernet ready IQ6 Dock with fresh air port plus 4 calibration gas inlet ports, software, installation disks and manuals.

12-039

Demand flow regulator*

54-05-001

Calibration gas tank holder

*Note: Demand flow regulators, calibration gas and Biosystems PhD6 sold separately.

 

Return to PhD 6


Return to SMG/interlink®
For more information  Email Mail  SMG/Interlink®
Interlink Marketing Corporation
dba SMG/interlink®
PO Box 260795
Plano, Texas 75026
Toll free 1-800-804-6196
Ph: 972-985-0883
Fx: 972-985-3252
2203 Glen Forest Ln
Plano, Texas 75023

credit card logos

Copyright © 1997-2012 Interlink Marketing Corporation

Home | Anemometers | Borescopes | Calibration gases | Gas detectors | Heat stress monitors | IAQ monitors | IR  cameras | Light/UV meters | Manometers | Moisture meters | Noise dosimeters | pH meters | Pitot tubes| Radiation meters | Sampling pumps | Sound meters | Thermometers | Other resources

SiteLock