ZoneGuard
Single Channel Fixed Gas Detection from
Sperian Biosystems
(discontinued January 1, 2011)
The ZoneGuard is a microprocessor
based fixed gas detection system designed to accept the input from a single oxygen,
combustible or toxic sensor. ZoneGuard systems are designed to provide continuous
round-the-clock monitoring for a variety of common atmospheric hazards including
oxygen deficiency and/or enrichment, combustible gases and vapors, and specific
toxic contaminants such as carbon monoxide (CO), hydrogen sulfide (H2S),
sulfur dioxide (SO2), chlorine (Cl2),
phosphine (PH3), and nitrogen dioxide (N02). Sensors may
be integrally mounted to the ZoneGuard controller housing, or remoted up to 50
feet away from the controller. Remote detector assemblies are available in explosion
proof or non-explosion proof versions.  |
| All normal procedures, including
fully automatic calibration adjustment, are controlled with a single button located
at the controller. Other
standard features include two independently adjustable alarm set points, built-in
audible alarm, easily-read, backlit LCD display, bright LED alarm light indicators,
and relay contacts for low and high alarm conditions. Optional accessories include
externally mounted high intensity strobe lights and high intensity horn. |
|
Features
- Round-the-clock
monitoring
for a wide variety of atmospheric hazards
- Easy
to install and operate
- One
button operation
- Fully
automatic calibration adjustment
- Weatherproof
NEMA 4X controller housing
- Easy-to-read,
backlit LCD display
- Built-in
loud audible alarm
- Two
independently adjustable alarm levels
- Output
relays for low and high alarm conditions
- Optional
external strobe lights and high intensity horn
Technical
Specifications
| ZoneGuard Outputs | Low
and high alarm. DPDT relay - contacts rated 5 Amp at 250 VAC, non-inductive load |
| ZoneGuard Display | 8
character 14-segment backlit LCD for gas readings and other messages |
| ZoneGuard Indicators (LED) | Power
on: green; low alarm: amber; high alarm: red | | Audible
alarm | Built-in audible alarm
(85 dB at 3 feet) | | Power
Requirements | 110 VAC - 50/60
Hz | | Temperature
Range | System
components
designed to function over range of-40° F to 110° F (-40° C to 43° C)
(Type of sensor installed may modify range.) | | Humidity
Range | 0 to 100% RH |
| Intrinsic Safety | Sensors
installed in explosion proof remote housings: Classified by UL and CSA as Explosion-Proof
for Class I, Division 1, Groups A, B, C and D hazardous locations. |
| Weather Protection | Controller
housing: NEMA 4X enclosure (IP rating of 654) | | Dimensions | ZoneGuard
controller: 10" (25 cm) x 7.5" (19 cm) x 5.25" (13 cm) | | Wiring: | For
oxygen remote detectors use (minimum) 22 gauge AWG, 6 conductor twisted-pair shielded
with drain.
For toxic use (minimum)
22 gauge AWG, 4 conductor twisted-pair shielded with drain.
For
combustible use 18 gauge AWG, 4 conductor twisted-pair shielded with drain. |
Each ZoneGuard system
includes the controller with all standard alarms, relays and electronics
installed in a NEMA 4X fiberglass housing, and sensor. When remotely
mounted sensors are specified the components provided include
both the sensor and remote detector housing. Specify the type
of sensor and whether the sensor is to be housed in an explosion
proof or non-explosion proof sensor housing at the time the system
is ordered. (Combustible sensors may only be mounted in explosion
proof remote sensor housings.) Note: conduit, wire and other components
necessary to connect remotely located sensors with the instrument
controller are not included.
Zone Guard
ordering information
| ZoneGuard
system for |
With
integrally mounted sensor |
With
remotely located sensor in standard housing |
With
remotely located sensor in explosion proof housing |
| Part
No. |
Part
No. |
Part
No. |
| Oxygen |
54-16-90
|
54-16-900
|
54-16-901
|
| LEL combustible |
NA
|
NA
|
54-16-801
|
| Carbon monoxide |
54-16-01
|
54-16-010
|
54-16-011
|
| Hydrogen sulfide |
54-16-02
|
54-16-020
|
54-16-021
|
| Sulfur dioxide |
54-16-03
|
54-16-030
|
54-16-031
|
| Chlorine |
54-16-08
|
54-16-080
|
54-16-081
|
| Phosphine |
54-16-13
|
54-16-130
|
54-16-131
|
| Nitrogen dioxide |
54-16-09
|
54-16-090
|
54-16-091
|
|