ZoneGuard Single Channel Fixed Gas Detection from Sperian Biosystems
(discontinued January 1, 2011)



The ZoneGuard is a microprocessor based fixed gas detection system designed to accept the input from a single oxygen, combustible or toxic sensor. ZoneGuard systems are designed to provide continuous round-the-clock monitoring for a variety of common atmospheric hazards including oxygen deficiency and/or enrichment, combustible gases and vapors, and specific toxic contaminants such as carbon monoxide (CO), hydrogen sulfide (H2S), sulfur dioxide (SO2), chlorine (Cl2), phosphine (PH3), and nitrogen dioxide (N02). Sensors may be integrally mounted to the ZoneGuard controller housing, or remoted up to 50 feet away from the controller. Remote detector assemblies are available in explosion proof or non-explosion proof versions.

All normal procedures, including fully automatic calibration adjustment, are controlled with a single button located at the controller.

Other standard features include two independently adjustable alarm set points, built-in audible alarm, easily-read, backlit LCD display, bright LED alarm light indicators, and relay contacts for low and high alarm conditions. Optional accessories include externally mounted high intensity strobe lights and high intensity horn. 

Features

  • Round-the-clock monitoring for a wide variety of atmospheric hazards 
  • Easy to install and operate 
  • One button operation 
  • Fully automatic calibration adjustment 
  • Weatherproof NEMA 4X controller housing 
  • Easy-to-read, backlit LCD display 
  • Built-in loud audible alarm 
  • Two independently adjustable alarm levels 
  • Output relays for low and high alarm conditions 
  • Optional external strobe lights and high intensity horn 

Technical Specifications

ZoneGuard OutputsLow and high alarm. DPDT relay - contacts rated 5 Amp at 250 VAC, non-inductive load
ZoneGuard Display8 character 14-segment backlit LCD for gas readings and other messages
ZoneGuard Indicators (LED)Power on: green; low alarm: amber; high alarm: red
Audible alarmBuilt-in audible alarm (85 dB at 3 feet)
Power Requirements110 VAC - 50/60 Hz
Temperature RangeSystem components designed to function over range of-40° F to 110° F (-40° C to 43° C) (Type of sensor installed may modify range.)
Humidity Range0 to 100% RH
Intrinsic SafetySensors installed in explosion proof remote housings: Classified by UL and CSA as Explosion-Proof for Class I, Division 1, Groups A, B, C and D hazardous locations.
Weather ProtectionController housing: NEMA 4X enclosure (IP rating of 654)
DimensionsZoneGuard controller: 10" (25 cm) x 7.5" (19 cm) x 5.25" (13 cm)
Wiring:For oxygen remote detectors use (minimum) 22 gauge AWG, 6 conductor twisted-pair shielded with drain.
For toxic use (minimum) 22 gauge AWG, 4 conductor twisted-pair shielded with drain.
For combustible use 18 gauge AWG, 4 conductor twisted-pair shielded with drain.

Each ZoneGuard system includes the controller with all standard alarms, relays and electronics installed in a NEMA 4X fiberglass housing, and sensor. When remotely mounted sensors are specified the components provided include both the sensor and remote detector housing. Specify the type of sensor and whether the sensor is to be housed in an explosion proof or non-explosion proof sensor housing at the time the system is ordered. (Combustible sensors may only be mounted in explosion proof remote sensor housings.) Note: conduit, wire and other components necessary to connect remotely located sensors with the instrument controller are not included.

Zone Guard ordering information

ZoneGuard system for With integrally mounted sensor
With remotely located sensor in standard housing
With remotely located sensor in explosion proof  housing
Part No. Part No. Part No.
Oxygen
54-16-90
54-16-900
54-16-901
LEL combustible
NA
NA
54-16-801
Carbon monoxide
54-16-01
54-16-010
54-16-011
Hydrogen sulfide
54-16-02
54-16-020
54-16-021
Sulfur dioxide
54-16-03
54-16-030
54-16-031
Chlorine
54-16-08
54-16-080
54-16-081
Phosphine
54-16-13
54-16-130
54-16-131
Nitrogen dioxide
54-16-09
54-16-090
54-16-091

Return to top


Return to SMG/interlink®
For more information  Email Mail  SMG/Interlink®
Interlink Marketing Corporation
dba SMG/interlink®
PO Box 260795
Plano, Texas 75026
Toll free 1-800-804-6196
Ph: 972-985-0883
Fx: 972-985-3252
2203 Glen Forest Ln
Plano, Texas 75023

credit card logos

Copyright © 1997-2012 Interlink Marketing Corporation

SiteLock