Home button About button
Blog button
       

SMG/interlink®
Serving our customers since 1994

Instruments for Environmental, Health and Safety Professionals,
HVAC Engineers and Technicians, Manufacturing Engineers,
Quality Control and Laboratory Professionals




SMG/interlink
Biosystems Distributor



Biosystems Product Information

Multi-Gas Portables
Single Gas Portables
Accessories

PosiChek3 SCBA Test Bench

Posi USB SCBA Test Bench
Calibration Gases



 
 
 

 

Biosystems toxic gas detectors, confined space instruments, single gas monitor, multi-gas monitor, handheld gas detectors, PhD Lite, MultiVision, PhD2, PhD Ultra, PhD Plus, hazardous gas detectors, LEL, Combustible, Gas, O2, Oxygen, CO, Carbon Monoxide, datalogging, non-logging biosystems now sperianBiosystems toxic gas detectors, confined space instruments, single gas monitor, multi-gas monitor, handheld gas detectors, PhD Lite, MultiVision, PhD2, PhD Ultra, PhD Plus, hazardous gas detectors, LEL, Combustible, Gas, O2, Oxygen, CO, Carbon Monoxide, datalogging, non-logging


DISCONTINUED January 1, 2009
Service and parts available through December 31, 2010

PhD5 Replaced by PhD6

The Biosystems PhD5
Confined Space Gas Detector


Biosystems proudly introduces the ultimate in Confined Space Detectors: The PhD5 monitors up to five atmospheric hazards simultaneously, including oxygen, combustible gas, and up to three channels of toxic gas detection.

Choose from a wide variety of toxic sensors; including Biosystems' innovative new "Duo-Tox" two-channel CO/H2S sensor to measure both carbon monoxide and hydrogen sulfide when both hazards are present without cross interference.

Sensors available include:

  • Oxygen (02)
  • LEL combustible gas
  • Carbon Monoxide (CO)
  • Dual purpose CO/H2S
    - Provides nonspecific readout (
    CO+)
  • Reduced sensitivity to hydrogen (CO-H)
  • Sulfur Dioxide (SO2)
  • Sulfur dioxide, extended range (SO2-EXT)
  • Ammonia (NH3)
  • Chlorine (non-specific) (Cl2)
  • Chlorine (specific) (Cl2)
  • Chlorine dioxide (Non-specific) (ClO2)
  • Chlorine dioxide (specific) (ClO2)
  • Nitric oxide (NO)
  • Nitrogen dioxide (NO2)
  • Hydrogen cyanide (HCN)
  • Phosphine (PH3)

The Biosystems PhD5 is housed in a rugged, metal-plated case designed to stand up to the most demanding environments. While all procedures necessary for day-to-day operation, including fully automatic calibration adjustment, are still controlled through a single button, an easy-to-read graphics display and navigation keys to make the PhD5 even easier to use than earlier versions.

Biosystems PhD5 detectors may be ordered with or without datalogging. Datalogging PhD5 detectors may be additionally equipped with Biosystems' unique "Touch ID" automatic memory download system. The system uses small, nearly indestructible memory buttons to store user ID and location information for the environment being monitored. It even stores the language preferences of the instrument user. The inexpensive buttons can be attached to worker ID badges, key rings, or permanently mounted to the external structures of frequently entered confined spaces. All you need to do is touch the built-in reader to the button to automatically download the stored  information. Keeping good records is a critical part of every confined space program. With "Touch ID" keeping good records is made easy with the touch of a button!


The Ultimate Confined Space Gas Detector!


Remarkable performance at an affordable price:
  • Easy to use: All procedures necessary for day-to-day operation, including automatic calibration adjustment, are controlled through a single On / Off "Mode" button. 
  • Small package; rugged design: The PhD5 is completely sealed against the elements. The rugged metal-plated case is designed to minimize radio frequency interference. 
  • Four sensors / five channels of detection:Choose from O2, LEL, and a wide selection of substance-specific toxic sensors; or choose Biosystems' innovative new "Duo-Tox" two-channel CO/H2S sensor for the simultaneous measurement of both CO and H2S without cross interference
  • Automatic calibration adjustment: "One Button Auto Calibration" is available any time while the PhD5 is in normal operation. All you have to do is press the "Mode" button, attach the adapter, and flow gas to the sensors. All the adjustments are made automatically. 
  • Interchangeable NiCad or alkaline battery packs: Either type of snap-in pack provides up to 12 hours of continuous operation. 
  • Datalogging with "Touch ID": PhD5 detectors may be ordered with or without datalogging. Datalogging instruments may be additionally equipped with Biosystems' unique "Touch ID" automatic memory download system. "Touch ID" buttons store user ID, location information, and even the language preferences of individual users. With "Touch ID" keeping good records is yours with the touch of a button! 

PhD5 kit including manual and slip-on pump sample draw systems, leather case and carrying strap, reference manual, training CD, Confined Space Kit including standard-sized cylinder calibration gas, flow control valve, tubing and foam-lined Pelican-style waterproof case.


Ordering information: Each PhD5 detector is shipped complete with leather case, carrying strap, hand-aspirated sample draw kit, reference manual, quick reference card, and training video. Alkaline PhD5 detectors include an alkaline battery pack and a set of 3 AA disposable batteries. NiCad detectors include a NiCad battery pack and a charger, as well as a spare alkaline battery pack and a set of batteries. Add "A" or "N" to the part number to specify "Alkaline" or "NiCad". Add "D" to include "Datalogging". Add "T" to include both datalogging and "Touch ID". Add "C" to the part number to order as a complete "Confined Space Kit" which includes calibration gas, regulator, fittings, and foam-lined carrying case. Only the most common configurations are listed below!

DESCRIPTIONPart Number
PhD5 with no sensors installed
54-24-00000
PhD5 with LEL / O2
54-24-30000
PhD5 with LEL / O2 / CO
54-24-30100 
PhD5 with LEL / O2 / CO+ 54-24-30500
PhD5 with LEL / O2 / H2S
54-24-30200 
PhD5 with LEL / O2 / CO / H2S
54-24-30102 
PhD5 with LEL / O2 / "Duo-Tox" CO / H2S
54-24-31400 
PhD5 with LEL / O2 / SO2 54-24-30300
PhD5 with LEL / O2 /CO/ SO254-24-30103
PhD5 with LEL / O2 /H2S/ SO254-24-30203
PhD5 with LEL / O2 / SO2 / "Duo-Tox" CO / H2 54-24-31403 
PhD5 with LEL / O2 / SO2 / "Duo-Tox" CO / NH3
54-24-31421
PhD5 with LEL / O2 / SO2 / "Duo-Tox" CO / Cl2 (non specific)54-24-31408
PhD5 with LEL / O2 / SO2 / "Duo-Tox" CO / NO2  54-24-31409
PhD5 with LEL / O2 / SO2 / "Duo-Tox" CO / HCN54-24-31410
PhD5 with LEL / O2 / SO2 / "Duo-Tox" CO / ClO2 (non specific)  54-24-31412
PhD5 with LEL / O2 / Ph3 / "Duo-Tox" CO / PH3 54-24-31413 
PhD5 with LEL / O2 / SO2 / "Duo-Tox" CO / SO2 -Ext  54-24-31415
PhD5 with LEL / O2 / SO2 / "Duo-Tox" CO / Cl2 (specific)  54-24-31418
Motorized continuous sample pump 54-27-0101 
Calibration kit for PhD5. Includes foam-lined carrying case with room for up to 3 cylinders of calibration gas. Kit contains one 12-023 regulator and other fittings. Does not include gas.
54-27-0501
MHP-1 remote vibrating alarm unit with 20' cable. Requires optional connector on instrument
54-27-0902
Five instrument 110 VAC slip-in multi-charger for PhD5. Includes power supply
54-27-0204
Spare alkaline battery pack for PhD535-0219
Spare NiCad battery pack for PhD535-0214
PhD5 Complete Upgrade Kit. Includes datalogging board, download cradle, BioTrack software, computer cable and manual
54-27-0606
Plug-in datalogging board for PhD554-27-0601
PhD5 Datalink Software kit (includes software and manual only)
54-27-0603
PhD5 Datalink Kit. Includes download cradle, BioTrack software, computer cable and manual
54-27-0605
Touch ID programming kit 54-27-0802 
Touch ID buttons (includes 10 unprogrammed buttons) 54-27-0805 
Touch ID wall mounts (includes 10 wall mounts for Touch ID buttons) 54-27-0806 
Touch ID key ring mounts (includes 10 key ring mounts for Touch ID buttons) 54-27-0807 


Return to SMG/interlink®
For more information  Email Mail  SMG/Interlink®
Interlink Marketing Corporation
dba SMG/interlink®
PO Box 260795
Plano, Texas 75026
Toll free 1-800-804-6196
Ph: 972-985-0883
Fx: 972-985-3252
2203 Glen Forest Ln
Plano, Texas 75023

credit card logos

Copyright © 1997-2012 Interlink Marketing Corporation

SiteLock