testo 535 Carbon Dioxide (CO2) Meter
|
The testo
535 is the easiest way to measure CO2 for indoor air
quality (IAQ) surveys. Poor air quality in rooms, characterized
by high CO2 levels (above 1,000 PPM CO2) and poor air circulation,
leads to tiredness, lack of concentration and is associated with
Sick
Building Syndrome.
| ![]() |
![]() | ![]() |
Technical
data - testo 535
| |
|
Sensor |
2 channel infra red absorption principle |
|
Display Units |
ppm/volume % |
| Display |
LCD. 2 Lines 0.433 inch / 11mm digit height |
|
Measuring Range |
0 - 9999 ppm CO2, (0 to 1%
vol. % CO2) |
|
Accuracy |
0 to 5,000 ppm, ±(50 ppm +2% of m.v.) 5,000 to 9.999 ppm, ±(100 ppm +3% of m.v.) |
|
Resolution |
1ppm or 0.001 volume % |
| Storage temperature |
-4.0...158.0 °F, -20... +70 °C |
|
Operating temperature |
32.0...122.0 °F, 0... +50 °C |
|
Operation humidity |
0.0...99.0 % |
| |
9V battery |
| |
>6 hours, auto off 10 minutes |
| Weight |
10.5 oz, 300 g |
| Dimensions (LxWxH) |
7.41 x 2.22 x 1.64 in, 57 x 190 x 42 mm |
|
Warranty |
2 years |
testo
535 Kit & Accessories
|
Part
Number |
|
| testo
535, CO2 meter with integrated probe, batteries and factory calibration
certificate |
0560 5350 |
899.00
|
| testo fast IR
printer with 1 roll of thermal paper and 4 AA size batteries |
0554 0549 |
349.00
|
| Spare
thermal paper for printer (6 rolls) Measurement data documentation
legible for up to 10 years |
0554 0568 |
|
| NIST calibration certificate. CO2
probes; single point calibration at 5000
ppm |
0520
0033 |
call
|
|
Return
to SMG/interlink® Copyright © 1997-2012 Interlink Marketing Corporation Home | Anemometers | Borescopes | Calibration gases | Gas detectors | Heat stress monitors | IAQ monitors | IR cameras | Light/UV meters | Manometers | Moisture meters | Noise dosimeters | pH meters | Pitot tubes| Radiation meters | Sampling pumps | Sound meters | Thermometers | Other resources
|